These meters employ a patented ultrasonic technique to measure a form of turbulence created in the flow stream. The meters have no moving parts and are virtually maintenancefree. A vortex meter primary flow element produces a series of oscillations of pressure. Flow measurement is the quantification of bulk fluid movement. The result is a simpler, more reliable design that is more sensitive to flow and less sensitive to noise. The strohaul number is the ratio between the vortex interval i and the shedder bar width d. Vortex flow meters have been appreciated by users as volume flow meters, which can, in principle, be applied to any flow measurement of liquid, gas, or steam.
Vortex shedding flow meter, easy installation, low cost, analog and 420ma output. The flowmeters case features a 4digit local display to show the current flowrate measurement and red warning lights to visually indicate high and low flowrate alarms. A0019373 the calibration factor kfactor is used as the proportional constant. The rvl series vortexshedding flow meter is a generalpurpose electronic liquid flow meter. Vortex flow meter manufacturers suppliers iqs directory. The rngrwgrwbg series vortex shedding flow meter family is designed to provide accurate and repeatable gas flow measurement. Vortex tech nology yields a meter with no moving parts to hang up or wear. Sierra was the first to offer this unique solution for measuring the mass flow of gases, liquids and steam. The maximum temperature for integral electronics is dependent on the ambient temperature where the flowmeter is installed. Vortex flow meter rvl series vrxds01586en03 may 2015 product data sheet description the rvl series meter uses vortexshedding technology for repeatable flow measurement accurate to 1 percent of full scale. Heinrichs messtechnik gmbh instruction manual dvh dve page 6 of 102 2. This figure is a plot showing the strouhal number st, stdfvsu versus the reynolds number re, reud.
The frequency of the vortices shedding is proportional to the fluid velocity. The analog 420 ma output signal offers your choice of volumetric or mass flow rate. The meter has no moving parts, and any potential for fluid contamination is eliminated by the corrosionresistant all plastic. Simulation of current and binary output manual process execution.
Vortexmaster fsv430, fsv450 vortex flowmeter abb group. Vortex flowmeters, also know as vortex shedding flowmeters or oscillatory flowmeters, measure the vibrations of the downstream vortexes caused by a barrier in the moving stream. Metering of fluids at high velocities with vortex shedding. Port sizes available from 38 three eighths inches to 2 two inches in diameter. The 83 series vortex flowmeter is available in 3 electonics versions, as shown in the table below. Vortex shedding flow meter operating under the same principle of the vortex shedding measurement, this type of vortex flow meter is suitable for viscous,clean, or dirty waterlike liquids that are compatible with brass, pvdf, and fkm.
Eliminate bypass piping for critical process installations. Usually the vortex interval is about six times the shedder bar width. Racine vortex rvl series vortex liquid flow meters. The development of a multichannel vortex flowmeter using a. If the cylindrical structure is not mounted rigidly and the frequency of vortex shedding matches the chimneys constructed of thinwalled steel tube can be sufficiently flexible that, in air flow with a speed in the critical range, vortex shedding can drive the chimney into violent oscillations that can damage or destroy the chimney. Our calibration capabilities include a wide range of flow rates, temperatures, and pressures utilizing numerous test gasses. The result is a meter capable of withstanding extremes of temperature, vibration, magnetic field and radiation, whilst operating in hazardous areas without expensive associated ex rated electronics. Picture of the fibre optic vortex flow meter in the donau test loop of shell. The fibre optic cable is the yellow cable shown left of the meter. The meter has no moving parts, and any potential for fluid contamination is eliminated by the meters corrosionresistant all plastic.
The vortex flowmeter is a broadspectrum flow meter which can be used for metering, measurement and control of most steam, gas and liquid flow for a very unique medium versatility, high stability and high reliability with no moving parts, simple structure and low failure rate. As shown in picture, in the meter body vertical insert a triangular prism root. The outputs include 420 ma and pulse for flow rate, as well as high and low alarms. Vortex shedding flow meter is suitable for measuring steam flow rate as well as liquids and gases. The flowmeter contains no moving parts for low maintenance and features a turndown ratio of at least 30. Vortex shedding flow meter performance at high flow. The rvl series meter utilizes vortexshedding technology to provide a repeatable flow measurement accurate to 1% of full scale. Flow monitors vortex shedding flowmeter description this flowmeter is made for water, waterglycol coolant of low viscosity fluids. The flapping of a flag is probably the most common example of this effect. Vortex shedding information about the vortex range vortex and other types of oscillatory flow meters utilize the behaviour fluid oscillations in order to derive flow rate. Sensitivity to variations in the process conditions are low and with no moving parts have relatively low wear compared to other types of flow meters. They rely on vortex shedding and require a certain minimum flow velocity to generate the vortices the frequency is linearly related to the fluid velocity. A market leading process measurement device, the versaflow vortex shedding flow meter is designed with steam and gas applications in mind. Ky instrument emag luxz intelligent vortex precession flow meter the luxz series intelligent vortex precession flow meter is the new type gas flow instrument with domestic leading level developed by our company.
Basic working principle of vortex flowmeter instrumentation. It features the functions of flow rate, temperature and. Vortex flow meters operate under the vortex shedding principle, where an oscillating vortexes occur when a fluid such as water flow past a bluff. Vortex meters see the most use in terms of steam application, since in relation to alternative forms of flow measurement, a vortex flow meter used as a steam flow meter features no moving parts, has a long functional working life, and is not too expensive. Minimum required backpressure is 10 psig at maximum flow and at 70 f 21 c. The dvz senses the flow rate of low viscosity liquids using the vortex shedding principle. Therefore, the frequency of vortex shedding is proportional to the volume flow. Ultrasonic waves are transmitted through the side wall. The versaflow vortex shedding flow meter detects the vortices that are created by a process medium going past a bluff body. The universal flow monitors ufm vortex shedding flow meter is designed for monitoring wateradd on concrete trucks. The three wire version power supplied separate from the. Vortex shedding bluff body receiver flow housing transmitter ultrasonic waves karman vortex.
Options for a 0 to 5 vdc or a frequency output proportional to the volumetric fl ow rate are also available. In fluid dynamics, vortex shedding is an oscillating flow that takes place when a fluid such as air or water flows past a bluff as opposed to streamlined body at certain velocities, depending on the size and shape of the body. We reserve the right to change the technical data in this manual in the light of any technical. Flow monitors vortex shedding flowmeter and temperature transmitter ct 142 inch flow and temperature transmitter maximum flow ranges from 4200 gpm 15750 lpm max pressure 300 psi 20 bar temperature range 32210f 299c flow temp coolpoint with rotatable enclosure viton is a registered trademark for dupont performance elastomers. Vortex flow meters operate under the vortex shedding principle, where an oscillating vortexes occur when a fluid such as water flow past a bluff as opposed to streamlined body. If the arrangement is symmetrical the swirls will be shed from alternate sides of the obstruction. The vortex shedding meter provides a linear digital or analog output signal without the use of separate transmitters or converters, simplifying equipment installation. Titan discuss flow meter vortex shedding if you place an obstruction such as a bluff body in a fluid stream vortices will be formed downstream of the impediment. Flow meter manuals, drawings, certifications, and other documents. Higher backpressures are required at elevated temperatures and occasional surges to 125% of maximum flow. Volume flow measurement is enough for substances with small variations in density such as liquid. Sv series vortex flow meter in welding applications, it is essential to control the flow rate and tempera ture of cooling water to prolong the life of the welding tip and to assure that the weld cools rapidly for optimum quality.
When the strohaul number is fixed,the flow velocity can be measured by counting the number of votices. Pfa vortex flowmeter as fluid passes through the flow chamber, karman vortices are created, with frequency proportional to flow velocity. Find vortex flow meter companies that can design, engineer, and manufacture vortex flow meter to your companies specifications. Dvh dve vortex flowmeter operating manual kobold usa. This property of the flow meter makes it very suitable for use in steambased oil recovery applications. Final 20140922 performance testing fibre optic based.
Tno has developed a fibre optic based vortex shedding flow meter, which is specifically designed to also estimate the amount of liquid present in a two phase flow. Vortex flow meters are suitable for measuring steam as well as a variety of liquids and gases. Numerical simulations of bluff body shapes such as circular, rectangular and equilateral triangular have been carried out to understand the phenomenon of vortex shedding. Vortex shedding sure flow products flow meter supplier. Digital vortex mass flow meters all feature large lcd display, shows the instantaneous instant flow rate, total flow, temperature, and density in user selectable units. Thorntons pfa flowmeter combines the vortex shedding principle with an advanced ultrasonic detection system. This article uses material from the wikipedia article vortex flow meter, which is released under the creative commons attributionsharealike license 3. Product data sheet fmvs83a model 83 vortex shedding. Flow monitors plastic vortex shedding flow rate transmitters description the p420. The vortex meter in a vortex flow meter, the bluff body is known as a shredder bar.
It is for this reason that this type of flow meter is sometimes referred to as a vortex shedding flow meter. Plastic vortex meters cx series open email download. With builtin temperature compensation as a standard feature and optional integral pressure compensation, it is the first choice for saturated steam, superheated steam and compensated gas flow measurement. Vortex shedding flow meter, also called vortex flow meter. Emco engineering measurements companydro flow series of vortex flowmeters are designed specifically for flow water measurement. The vibrating frequency of the vortex shedding is related to the velocity of the flow. Maximum flow ranges from 4200 gpm 22750 lpm max pressure 300 psi 20 bar temperature range 35f 254c viton is a registered trademark for dupont performance elastomers.
User manual flow meters from badger meter, dynasonics. The frequency of these vortices can be equated into flow velocity, which, in turn, is used to calculate volumetric flow rate. Product data sheet fmvs83a model 83 vortex shedding flowmeter. Refer to the product reference manual for typical flow rates for common applications.
These applications are found in most process industries, including rubber, steel, fabrication, manufacturing. F l o w m o n i t o r s universal coolpoint description. The rosemount 8800d critical process vortex increases process availability and enhances overall safety. Incorporates temperature sensor into the vortex meter using the shedder bar as a thermowell, which keeps the vortex and temperature sensors isolated from process for easy verification and replacement.
Flow meter calibrations as one of the largest commercial calibration laboratories in north america, we provide a comprehensive range of calibration services. The variation of st with re is discussed so that the audience has an understanding of what flow features. Meter accuracy is good over a potentially wide flow range, although this range is dependent upon operating conditions. The shedding frequency is a function of the dimensions of. Options for a 0 to 5 vdc or a frequency output proportional to the volumetric flow rate are also available. Yokogawa yf108 vortex shedding making use of the individual meter evaluation results, combined with experience of wib member flow experts, an application guideline for vortex flowmeters was prepared by tno. Archived pdf from the original on 25 september 2015. Vortex flow meters flow instrumentation badger meter. Classic digitalyewflo vortex flow meters are available in a number of different sizes ranging from 12inch to 16inch. The rvl series vortex shedding flow meter is a generalpurpose electronic liquid flow meter. Vortex flow meter manufacture silver automation instruments offer china factory made vortex type flow meter at low price cost rugged construction, our factory also deliver the vortex shedding flow meter fast. Vortex shedding flow meter performance at high flow velocities.
Combined with flexible tuning, the model 84 has the widest flow range capability of any vortex meter. Vortex shedding sure flow products flow meter supplier, flow switch, and sure flow product store. Browse online, or one of our applications engineers can help you choose the right product for your application. This will minimize potential measurement errors by allowing the condensate or solids to flow under the shedder bar without interrupting the vortex shedding. The vortex shedding frequency around a bluff body can be calculated as. The fv200 series vortexshedding fl ow meter is a generalpurpose electronic liquid fl ow meter. The purpose of these guidelines was to give some rules of thumb to realise the best possible vortex flowmeter performance. Reducer vortex extends the measurable flow range, reduces. Vortex technology yields a meter with no moving parts to hang.
A vortex flow meter is a flow measurement device best suited for flow measurements where the introduction of moving parts presents problems. Smartflow addresses this limitation by combining vortex shedding flow measurement techniques with fbg sensing advantages. Top vortex flow meter brands such as below, has excellent performance. With d and t electronics, combinations of the output signals can be provided, depending on whether the flowmeter is wired as a 2, 3 or 4 wiredevice. Flow monitors vortex shedding flowmeter cp 342 inch maximum flow ranges from 25200 gpm 95750 lpm max pressure 300 psi 20 bar temperature range 32210f 299c coolpoint with rotatable enclosure option viton is a registered trademark for dupont performance elastomers. Then contact the vortex flow meter companies through our quick and easy request for quote form.
The fv100 is an inline flow meter that utilizes the vortex shedding measuring principle. The piping system must create some backpressure on the meter to allow vortex formation and to prevent cavitation, especially at full flow. Vortex flow meters have now become very popular among the researcher to use it in industries and companies. They are available in industrial grade, brass or all plastic construction. As fluid moves across a vortex meter shedder bar, vortices form. A small obstruction called a bluff body is placed in the flow path. Higher backpressures are required at elevated temperatures and. Vortex flowmeters are used in numerous branches of industry to measure the volume flow of liquids, gases and steam. The thermister is excellent sensing method when mounted on front face where very.
The strouhal number st is a dimensionless number which is a function of the shape and size of the vortex shedder. The system shall utilize the vortex measurement principle by monitoring the shedding frequency of. Karman vortex flow meter flow knowledge keyence america. Vortex flowmeter flange card type vortex flowmeter tempersturepressure compensaton type vortex flowmeter inserted type vortex flowmeter sanitaryclamp type lugbtype 2 vortex flow sensor measuring the flow of liquid of steam,gas and low viscosity relationship. Available with wafer style or flanged style ansi class 150 to ansi class 900, digitalyewflo has the size you need. The primary sensing element of a volumetric flow meter is a vortex shedding velocity sensor. Vortex shedding flow meters have been in use for many years. Vortex flow meter based on phenomenon is known as vortex shedding. The shedder bar is shaped to allow process fluid to separate and generate vortices around. It can be mounted with flow in any direction and the display can be rotated 180 degrees in the field for viewing conve nience.
Vortex shedding flow meter designed for gas flow, steam or liquids volume flow, standard volume flow or mass flow measurement. Model 83 vortex shedding flowmeter flow measurement measure liquids, gases and steam wide rangeability pulse, analogue and digital outputs easy installation no moving parts cenelec, csa, fm and saa approval versions include sanitary, nace and remote electronics general description the 83 series flowmeters measure flow by. Provide a loop powered vortex flow meter consisting of flanged full body or wafer design for the measurement of liquid, gas, or steam media. Three vortex shedding cycles or 300 ms, whichever is greater.
In this flow, vortices are created at the back of the body and detach periodically from either side of the body. When there is a columnshaped obstruction vortex shedder in flowing fluid, it will generate alternating vortices downstream. Temperature compensated capability for saturated steam. This flow meter vortex shedding phenomenon is true for both gases and liquids.
In a vortex flow meter, an obstruction in the flow path, often referred to as a shedder bar, serves as the bluff body. These shed vortices are carried downstream in the flow and are detected by vortex shedding and fluidic flow meters, which measure thevelocityof liquids and gases such as water,cryogenicliquids,boiler feed water,hydrocarbons, chemicals, air, nitrogen,industrial gases, and steam flowing through the pipe. Final 20140922 performance testing fibre optic based vortex. When fluid moves in a pipe then vortices will form when flow hit the bluff body. Pdf design and development of 16 inch vortex flow meter with. Vortex flowmeter for vapor, liquid and gas, with integrated binary output. Compressed air flow measurementvortex shedding meter. This technology works by inducing fluctuations in the fluid properties such as pressure, density or viscosity which can be converted into a flow rate. Processing technology make measurement more stable and reliable. Working principle of vortex flow meter instrumentationtools. An everyday example of a vortex shedding phenomenon is a flag waving in the breeze. Ky instrument emag luz intelligent vortex shedding flow meter the electromagnetic velocity meter is portable instrument used for measuring the velocity, flow and level. Applications in the chemicals and petrochemicals industries, for example, in power generation and heatsupply systems involve widely differing fluids.
1002 12 827 606 520 1393 1497 202 821 1361 187 992 1059 159 717 646 936 428 463 555 277 1244 270 512 1198 1210 1135 1057